Snow Load in the UK, Worked Through for One Roof (BS EN 1991-1-3)
10 October 2026 · 9 min read

UK snow load worked through for a 35° duopitch roof: ground snow of about 0.5 kN/m², 0.33 kN/m² on plan and 0.80 kN/m onto each wall. BS EN 1991-1-3.
What is the snow load on a UK roof?
For a typical lowland UK site, the characteristic ground snow load is roughly 0.3 to 0.6 kN/m². The roof snow load is that value multiplied by a shape coefficient, which is 0.8 for pitches up to 30°. So a flat or gently pitched lowland roof usually carries about 0.25 to 0.5 kN/m² of snow, measured on plan. Steeper pitches carry less, and above 60° the code takes snow as zero.
| Item | Typical UK value | Source |
|---|---|---|
| Roof snow load | s = μi × Ce × Ct × sk | BS EN 1991-1-3, cl. 5.2 |
| Ground snow load, sk | About 0.3 to 0.6 kN/m² (lowland, from zone and altitude) | UK NA to BS EN 1991-1-3 |
| Exposure coefficient, Ce | 1.0 | UK NA to BS EN 1991-1-3 |
| Thermal coefficient, Ct | 1.0 | BS EN 1991-1-3, cl. 5.2 |
| Shape coefficient μ1, 0° to 30° | 0.8 | BS EN 1991-1-3, Table 5.2 |
| Shape coefficient μ1, 30° to 60° | 0.8(60 - α)/30, zero at 60° | BS EN 1991-1-3, Table 5.2 |
| Combination factor for snow, ψ0 | 0.5 (sites up to 1000 m) | UK NA to BS EN 1990 |
These are typical values; check them with a competent engineer against the current standards and your exact site before using them for design.
What is the snow load formula?
The roof snow load for a persistent design situation (the normal, everyday case) is:
s = μi × Ce × Ct × sk
- sk is the characteristic ground snow load for the site, in kN/m².
- μi is the roof shape coefficient. It turns ground snow into snow on your roof, based on pitch and shape.
- Ce is the exposure coefficient. It allows for wind blowing snow off an exposed roof.
- Ct is the thermal coefficient. It allows for heat melting snow on a poorly insulated roof.
The result is in kN/m² measured on plan, which means per square metre of horizontal area, not per square metre of slope. That is why it drops straight into a load takedown: you multiply by a plan width and you are done. No slope-length correction is needed.
How do you find sk in the UK?
The UK National Annex gives a zone map (Figure NA.1) and a formula that adds an allowance for altitude:
sk = [0.15 + (0.1Z + 0.05)] + (A - 100)/525
- Z is the zone number read from the map.
- A is the site altitude above sea level in metres.
- sk comes out in kN/m².
At 100 m the altitude term is zero, and the formula gives 0.30 kN/m² in zone 1, 0.40 in zone 2 and 0.50 in zone 3. Each extra 100 m of altitude adds about 0.19 kN/m². High ground in Scotland, Wales and the north of England can be well above 1 kN/m².
Below 100 m the altitude term goes negative and the formula gives a smaller value. The National Annex does not set a lower limit on A, so the reduction is allowed: zone 2 at sea level gives 0.40 - 0.19 = 0.21 kN/m². You can still choose to use A = 100 m as a floor, which is conservative. Decide which approach you are using and write it down.
The annex warns that the map may not capture unusual local effects, such as local shelter from the wind, which can increase local snow loads, or valleys in mountainous areas that funnel snow. If you suspect conditions like these on a coastal site below 100 m, it says to use the map value without the altitude adjustment, in effect A = 100 m. In other cases it says to consult the Met Office.
Read the zone off the map for the actual site.
What do Ce and Ct do?
Ce and Ct are the two correction factors people forget about, because in UK practice they are almost always 1.0.
- Ce = 1.0. The UK National Annex takes the normal exposure value. It does not reduce snow for windswept roofs.
- Ct = 1.0. Only a roof that loses a lot of heat, such as single glazing over a heated space, can justify a lower figure. For a house roof, use 1.0.
With both at 1.0, the working formula for most UK buildings is s = μ1 × sk.
What roof shape coefficient do you use?
The shape coefficient μ1 depends on the roof pitch α. For monopitch and duopitch roofs, BS EN 1991-1-3 Table 5.2 gives:
| Pitch α | μ1 |
|---|---|
| 0° to 30° | 0.8 |
| 30° to 60° | 0.8(60 - α)/30 |
| 60° or more | 0 |
Snow slides off steep roofs, so the coefficient falls to zero at 60°. A 35° roof gives 0.8 × (60 - 35)/30 = 0.67. The table assumes snow can slide off freely. If snow fences or other obstructions stop it, or the lower edge of the roof ends in a parapet, BS EN 1991-1-3 (clauses 5.3.2 and 5.3.3) says μ1 should not be reduced below 0.8.
A duopitch roof has three arrangements to check:
- Undrifted: μ1 on both slopes.
- Drifted, either way round: in the UK, the National Annex (Figure NA.2 and Table NA.1) replaces the Eurocode's drifted case. One slope carries no snow and the other carries a drifted coefficient: 0.8 up to 15°, 0.8 + 0.4(α - 15)/15 from 15° to 30°, 1.2(60 - α)/30 from 30° to 60°, and zero at 60° or more.
At 35° the drifted coefficient is 1.2 × 25/30 = 1.0, so the loaded slope carries 1.5 times the undrifted snow and the other slope carries none. That one-sided case matters for members and connections that are sensitive to unbalanced load. It can also give the nearer wall more snow than the undrifted case, so check both.
What about drifts at parapets and abutments?
Wind moves snow. Where a roof meets a taller wall, a parapet or a rooflight upstand, snow collects against it and builds up into a drift.
- The drift is deepest against the taller element and tapers away from it.
- Its size depends on the height of the step and on how much roof is upwind to supply snow.
- In the UK, the National Annex says to use Annex B of BS EN 1991-1-3 for drifts at multi-span roofs, at roofs next to taller buildings, and at projections and obstructions such as parapets. It classes these as exceptional drifts and says to treat them as accidental actions, so they are checked in the accidental design situation, with a partial factor of 1.0 on the drift load rather than 1.5.
- The drift load is local. It usually governs the roof members and the supporting wall near the step, not the whole building.
This article does not compute drifts. If your roof has a parapet, an abutment against a taller building, a valley or a lower roof next to a higher one, read Annex B and the UK National Annex directly. A drift can add several times the uniform snow load close to the step.
Worked example: a 35° duopitch house roof
Take a typical house roof:
- Duopitch, 35° pitch on both slopes.
- Zone 2 on the map, site altitude 150 m (assumed for this example).
- Trussed rafters span the full 4.8 m width of the building, from wall plate to wall plate. Each wall carries half the width of roof: a loaded width of 2.4 m.
- Ce = 1.0 and Ct = 1.0.
Step 1: ground snow load
sk = [0.15 + (0.1 × 2 + 0.05)] + (150 - 100)/525
= 0.40 + 0.095 = 0.495, say 0.50 kN/m²
Step 2: shape coefficient
μ1 = 0.8 × (60 - 35)/30 = 0.667
Step 3: roof snow load on plan
s = 0.667 × 1.0 × 1.0 × 0.50 = 0.333, say 0.33 kN/m²
Step 4: line load onto each wall
w = s × loaded width = 0.333 × 2.4 = 0.80 kN/m
That is the characteristic snow load delivered to each wall plate, per metre run. Add it to the roof dead load (tiles, battens, trusses, insulation, ceiling) to get the total roof reaction.
Loaded width explains how to find the width each wall picks up, and the free tributary area calculator does it for any shape of roof or floor panel.
Snow load only matters once you know which walls and beams pick it up, and the loaded width does that for you.
Try the example in the appDoes snow combine with the roof imposed load?
No. The UK imposed load on a roof that is only accessible for maintenance (category H) is 0.6 kN/m² on plan for slopes up to 30°. Under the UK National Annex to BS EN 1991-1-1 it reduces on steeper slopes in the same way as μ1: 0.6(60 - α)/30, and zero at 60°. BS EN 1991-1-1 says roof imposed load need not be applied at the same time as snow or wind.
So you check both as separate cases and take whichever is worse. For the undrifted case, both values follow the same pitch rule, so the comparison does not depend on pitch:
Undrifted snow governs only when 0.8 × sk > 0.6, i.e. when sk > 0.75 kN/m²
For most lowland UK sites sk is below 0.75 kN/m², so the maintenance load governs. In our example:
Roof imposed load at 35° = 0.6 × (60 - 35)/30 = 0.50 kN/m²
Line load onto each wall = 0.50 × 2.4 = 1.20 kN/m (governs)
Undrifted snow line load = 0.80 kN/m
Drifted snow, nearer wall = 1.0 × 0.50 × 2.4 × 3/4 = 0.90 kN/m
The drifted figure assumes the trussed rafter spans simply from wall to wall, so the snow on one slope splits three quarters to the nearer wall and one quarter to the further one. Snow governs on higher ground, in the snowier zones, and at drifts against parapets and abutments.
Snow does combine with the floor imposed loads below. When snow is the leading variable action, floor imposed load accompanies it with its own combination factor. When floor imposed load is leading, snow accompanies it with ψ0 = 0.5 (UK NA to BS EN 1990, sites up to 1000 m). For our example the design snow line load would be 1.5 × 0.80 = 1.20 kN/m as the leading action, or 1.5 × 0.5 × 0.80 = 0.60 kN/m as an accompanying one. Permanent loads come on top with their own factor. See characteristic vs design loads for how the factors are applied.
Where does this go in a load takedown?
Snow is a variable load at the top of your chain. Roof dead load and the worse of roof snow or roof imposed load go to the walls, then down to the foundations, along with every floor below. The order is the same as in the manual load takedown and the worked example. The UK floor and roof loads article lists the other typical values you will need, and solar panel roof loads covers what panels add.
If you would rather not repeat this for every roof, you can do the whole building in LoadTakedown.
FAQ
What is a typical snow load in the UK in kN/m²?
For most lowland sites the characteristic ground snow load is about 0.3 to 0.6 kN/m², found from the UK National Annex zone map and altitude. On a roof up to 30° pitch, multiply by 0.8 to get roughly 0.25 to 0.5 kN/m² on plan. Higher or more exposed sites can be much more.
Do I add snow load and the 0.6 kN/m² roof imposed load together?
No. The roof imposed load is a maintenance load and need not be combined with snow or wind. Check each case separately and design for the worse one. For pitched roofs the two follow the same pitch rule, so undrifted snow only governs where sk is more than 0.75 kN/m². Check the one-sided drifted case and any local drifts as well.
Is the UK snow load measured on the slope or on plan?
On plan. The shape coefficient already converts ground snow to a load per square metre of horizontal area. That is why you multiply by the plan loaded width, not the sloping length of rafter, when you work out the line load onto a wall.
Do I have to allow for snow drifts?
Where there is a parapet, an abutment to a taller building, a valley or a step in roof level, yes. In the UK these are exceptional drifts, worked out with Annex B of BS EN 1991-1-3 as an accidental design situation. They can add a lot of load locally, so work them out for any roof with a step.
What is the snow load formula?
s = μi × Ce × Ct × sk. The ground snow load sk comes from the UK National Annex zone map and altitude. Ce and Ct are normally 1.0, and μi is the roof shape coefficient. For most UK buildings that reduces to s = μ1 × sk.
Sketch your structure straight onto your drawings and get tributary loads for every wall and level, instantly.
Try the example in the app