← Tutorials

How to Check a Load Takedown: Six Quick Checks

9 October 2026 · 8 min read

structural engineeringload takedowncheckingmanual calculation
Red safety helmet resting on tarmac at a construction site

Six quick checks for any load takedown, from a total-weight balance to a ballpark kN/m test, worked on a two-storey UK house that totals 970 kN.

Try a worked exampleIn the app, no account needed

The quickest way to check a load takedown is to weigh the whole building a second, independent way and compare it with the sum of everything that reaches the foundations. If the two totals agree to within a few percent, nothing large has been missed or counted twice. Then run five quicker checks: loaded widths add up to the span, loads only grow going down, every load lands on something, the units and factors are consistent, and each answer is in the right ballpark.

On a house they take about ten minutes, and they catch the most common errors. They work the same whether the takedown was done by hand, in a spreadsheet or in software.

The example house

All six checks below use the same simple two-storey house, 8.0 m deep by 9.0 m wide:

  • Roof: tiled, on trusses spanning 8.0 m front to back. 0.9 kN/m² dead + 0.6 kN/m² imposed = 1.5 kN/m² (the full 0.6 is conservative above 30° pitch).
  • First floor: timber joists spanning 4.0 m from the front and back walls onto a central spine wall. 0.6 kN/m² dead + 1.5 imposed + 0.8 partitions = 2.9 kN/m². The 0.8 is the cautious partition band; light timber studs fall in the 0.5 band (see typical UK floor and roof loads).
  • External walls: 102.5 mm brick and 100 mm medium dense block cavity, plastered inside, 3.6 kN/m² (3.35 for the masonry plus 0.25 for plaster, from wall self-weight; the rounder 3.5 used elsewhere is a rule of thumb), 5.0 m from ground level to eaves (2.6 m ground storey, 2.4 m upper storey).
  • Spine wall: 100 mm block, plastered both sides, 1.9 kN/m², ground storey only, 2.4 m high.
  • Ground floor: bears on the ground, so it is not in the takedown.

All values are characteristic. They are typical values; check with a competent engineer before using them on a real job. The manual load takedown article explains where they come from.

The takedown gives these line loads at ground level. The wall below ground, the footing and its backfill come on top, as foundation load from a wall shows for W1:

WallRoof (kN/m)Floor (kN/m)Self-weight (kN/m)Total (kN/m)Length (m)Total (kN)
Front, W11.5 × 4.0 = 6.02.9 × 2.0 = 5.83.6 × 5.0 = 18.029.89.0268
Back, W26.05.818.029.89.0268
Sides, W3 and W418.018.02 × 8.0288
Spine, W52.9 × 4.0 = 11.61.9 × 2.4 = 4.616.29.0146
Sum970

1. Does the total weight balance?

Work out the weight of the building a second way, without using any loaded widths, and compare it with the sum of the foundation loads.

Roof        72 m² × 1.5 kN/m²          = 108 kN
First floor 72 m² × 2.9 kN/m²          = 209 kN
External    34 m × 5.0 m × 3.6 kN/m²   = 612 kN
Spine       9.0 m × 2.4 m × 1.9 kN/m²  =  41 kN
Total                                  = 970 kN
The example house weighed two ways: roof 108, first floor 209, external walls 612 and spine wall 41 kN on one side, footing totals 268, 268, 288 and 146 kN on the other, both adding to 970 kN
Weigh the building once, add up the footings once. The two totals should agree.

That matches the 970 kN in the table. On a real job the two numbers rarely match exactly, because of openings, overlaps at corners and rounding. Within about 5% is fine. A bigger gap almost always means an area that is in one calculation but not the other (a bay window, a roof overhang, a stair void deducted in only one), or an area counted on two walls.

This is the most valuable check because it does not rely on the loaded widths, spans or wall-by-wall splits being right. It only asks whether everything that goes in comes out at the bottom.

2. Do the loaded widths add up to the span?

At every level, the loaded widths across a span should add back to the span, with no gaps and no overlaps.

  • Roof: W1 takes 4.0 m and W2 takes 4.0 m. That adds to the 8.0 m truss span.
  • First floor: W1 takes 2.0 m, W5 takes 4.0 m and W2 takes 2.0 m. That adds to the 8.0 m depth.

The usual mistake is giving an internal wall a full span from each side, or forgetting that a wall in the middle of two spans takes half of each. If the floor is not a simple rectangle, check the areas instead: the tributary regions on each level should add up to the floor area. The loaded width article covers continuous joists and cantilevers, where the half-and-half split no longer applies.

3. Do the loads only grow going down?

Follow each wall from the top. Its line load should go up at every level, by roughly the floor load it picks up plus one storey of its own weight. In this house W1 goes from 6.0 kN/m at the eaves to 29.8 kN/m at ground level. W5 starts at first floor with 11.6 kN/m and ends at 16.2 kN/m.

A wall whose load drops on the way down has lost something, usually a level that was skipped. A jump far bigger than one storey's worth usually means a beam reaction or an upper wall has been added twice.

4. Does every load land on something?

Every load in the takedown must end up on a footing. Check three places in particular:

  • Beams. Each end reaction must appear as a point load on the wall or post below it.
  • Walls that don't stack. An upper wall with no wall beneath it is supported by the floor, which distributes its load sideways to the walls either side. See walls that don't line up.
  • The roof. Trussed rafters usually span the full width onto the external walls, so an internal wall gets no roof load. In this example the spine wall carries no roof. If the roof is cut, or the trusses bear on an internal wall, the split changes completely, so write down which you assumed.

5. Are the units and factors consistent?

Most arithmetic errors in a takedown come from units or factors, not from geometry.

  • kN/m², kN/m and kN. Area loads times a width give a line load. Line loads times a length give a point load. If a column says "kN/m" and contains 268, something has been multiplied by a length too early.
  • kg and kN. Manufacturers quote kg/m² or kg/m³. Multiply by 0.00981 to get kN. A block "at 1400" is in kg/m³, which is 13.7 kN/m³, not 1400 kN/m³.
  • Characteristic and design loads. Keep them in separate columns. Bearing pressure checks against a presumed allowable pressure use characteristic loads. Member checks use factored loads (1.35G + 1.5Q). Mixing the two in one total is the error the manual load takedown article warns about.

6. Is each answer in the right ballpark?

Finally, compare each result with what similar buildings carry. As a rough guide for UK houses:

  • Two storeys, timber first floor: about 15 to 35 kN/m at ground level: 15 to 20 on walls carrying only their own weight, 25 to 35 on walls carrying floor and roof. This house comes out at 16 to 30 kN/m.
  • Two storeys, concrete first floor: about 40 to 60 kN/m on the walls that carry it. The manual load takedown example reaches 45 kN/m.
  • Bearing pressure: 29.8 kN/m on a 600 mm strip footing is 29.8 / 0.6 = 50 kN/m² before adding the substructure. With the wall below ground, the footing and its backfill it is 70 kN/m² gross, as worked in foundation load from a wall. That is well under typical presumed allowable pressures for firm ground, so a much higher figure on a similar house deserves a second look.

A result well outside these ranges is not necessarily wrong. A three-storey wall or a wall carrying a water tank will be higher. But you should be able to say why.

A checklist for the calculation sheet

CheckWhat to compareTypical cause of a fail
Total weightIndependent total vs sum of foundation loadsMissed area, double counting
Loaded widthsLoaded widths vs span on each levelFull span given to an internal wall
Loads grow going downEach wall level by levelSkipped level, reaction added twice
Every load landsBeam reactions, upper walls, roofOffset wall or beam end not picked up
Units and factorskN/m², kN/m, kN; Gk, Qk, ULSkg not converted, factored and unfactored mixed
BallparkkN/m against similar buildingsAny of the above

Write the checks on the sheet with the takedown. A checker who sees the total-weight balance at the bottom of the page will trust the rest of it far more quickly. The worked example shows a full takedown these checks can be run against.

Free load takedown spreadsheet

SLS and ULS line loads for every wall, a UK load library and a footing width guide. Free Excel file, no account.

Get free spreadsheet

FAQ

How do I check a load takedown quickly?

Add up the weight of the whole building independently: each floor and roof area times its load, plus every wall's area times its weight. Compare that with the sum of all the foundation loads from the takedown. If they agree to within about 5%, nothing large is missing or double counted. Then check the loaded widths and units.

What is a typical foundation load for a two-storey house?

With timber floors and a tiled roof, external walls typically carry about 15 to 35 kN/m (characteristic) at ground level: about 25 to 35 kN/m where they carry floor and roof, less where they carry only their own weight. A concrete first floor raises that to around 40 to 60 kN/m on the walls supporting it. These are rough guides: always do the takedown for the actual building.

Should a load takedown use factored or unfactored loads?

Both, kept separate. Use characteristic (unfactored) loads to check bearing pressure against a presumed allowable pressure. Use design loads, typically 1.35 × permanent + 1.5 × variable, to check the masonry, beams and padstones. Never add the two together.

What are the most common errors in a load takedown?

Missing a floor area such as a stair void or bay, giving an internal wall a full span from both sides, forgetting a beam reaction or an offset wall, leaving loads in kg rather than kN, and mixing factored with unfactored loads. A total-weight balance catches the first three.

LoadTakedown carries every level down for you and keeps characteristic and design loads apart. Use it to check a hand takedown, or start from the free spreadsheet.

Sketch your structure straight onto your drawings and get tributary loads for every wall and level, instantly.

Try the example in the app